![Brusa EVB1-350-40-HP Technical Data And Start-Up Download Page 62](http://html1.mh-extra.com/html/brusa/evb1-350-40-hp/evb1-350-40-hp_technical-data-and-start-up_2821421062.webp)
Technical data
and start-up
EVB1-350/400-40-HP
62
PROCEDURE STEP
ILLUSTRATION / OTHER INFORMATION
10.
Switch terminal 15 to
high
(e.g. switch on ignition key
in vehicle).
The BMS is switched on / activated.
---
11.
Check the status and the current battery data of the
BMS with the Param Software
---
12.
If all the battery data is OK, switch pin 15 to
low
(e.g.
switch off ignition key in vehicle).
If the battery data is not OK, there is a fault.
Should you have any questions, please contact
our support service at the manufacturer address
given in chapter
---
13.
Pull the control plug out from the battery's female
connector (note the plug lock).
---
14.
Connect the ground cable to the grounding
screw (1).
Torque = 10 Nm
15.
Connect the HV supply.
---
16.
Unscrew the screws (1).