Technical data
and start-up
EVB1-350/400-40-HP
26
5.2
Improper Use
The carrying out of applications which do not conform to those stated in the technical documents and datasheets of
the manufacturer is viewed as improper use. Under consideration of the proper uses named in chapter
, the
following limits are set for the operation of the product EVB1-400-40-HP or EVB1-350-40-HP. The product may not
be used outside these limits. Operation outside the defined limits can lead to life-threatening situations.
EVB1-350-40-HP
EVB1-400-40-HP
UNIT
Permitted voltage range
290 - 400
324 - 448
V
Max. charging current
120
120
A
Max. discharging current
600
600
A
Min. ambient temperature - discharge
- 10
°C
Max. ambient temperature - discharge
+ 55
°C
Min. ambient temperature
– charge (0.3C
12A)
+0
°C
Nom. ambient temperature
– charge (3.0C
120A)
15
– 35
°C
Max. ambient temperature
– charge (1.0C
40A)
+ 45
°C
Min. coolant temperature on entry
+ 0
°C
Max. coolant temperature on entry
< + 40
°C
Maximum cooling circuit pressure
1.0
bar