Technical information
and start-up
BSC624-12V-B
56
9
Installation / initial start-up
DANGER
High voltage!
Danger to life!
Never touch the HV wires or HV connections without ensuring the absence of voltage
beforehand!
The device may only be connected by a qualified electrician!
Safety installations must never be by-passed or circumvented! Any resulting malfunctions could
have life threatening consequences!
INSTRUCTION
All electrical connections are to be fixed within a distance of < 30 cm from the device with a strain
relief in order to protect the cable and/or the cable tree at the control connector against vibration
and consequential damage.
Ensure that the HV battery used has a pre-charging unit. Any connection without pre-charging
unit may cause the formation of sparks / voltage peaks and thus damage to the device!
Procedure step
Illustration / other information
1.
Mechanically install the device in its specified
position.
Please refer to the installation instructions
See chap.
6.9 Dimensions and installation
---
2.
Connect the cooling water hoses (1).
See chap.
3.
Ventilate the cooling system.
Ensure that no trapped air is present in the
cooling system!
9.2 Ventilating the cooling system
---