Technical information
and start-up
BSC624-12V-B
48
by the internal or external identification.
The LV connector is not integrated into the interlock circuit.
For the wire bridge in the HV customer side connector the delivered wire has to be installed. The installed wire
bridge may not be removed or modified (e.g. extended)!
For customers using an alternative interlock concept (e.g. feeding of a square wave signal, comparison of the
voltage level in the beginning and in the end of the interlock loop), R4 may be optionally equipped with a 0
Ω
resistor in order to avoid any undesired voltage drop.
Please note that, in such case, the external interlock identification of the device no longer functions and
that, therefore, it must be deactivated in the PARAM software.
When placing the order, it is to be ensured that a device version which is suitable for the interlock concept to
be used is selected:
BSC624-12V-B01: R4 = 62R (this is a customer-specific version)
BSC624-12V-B02: R4 = 62R
BSC624-12V-B03: R4 = 0R
BSC624-12V-B04: R4 = 62R
BSC624-12V-B05: R4 = 0R
BSC624-12V-B06: R4 = 62R
BSC624-12V-B07: R4 = 0R