35
Technical information
and start-up
BSC624-12V-B
6.9
Dimensions and installation information
For the installation of the device, the following points must be generally adhered to:
Despite the existing IP protection, the device should only be exposed to environmental influences to the
extent required by the application.
The device may not be installed in the direct vicinity of heat sources (e.g. combustion motor).
The mechanical fixture is to be directed in a way that the device is installed in a fixed position and with as little
vibrations as possible.
The cable inlets and cooling water ducts should have enough space and must never touch components with
sharp edges.
All electrical connections are to be fixed within a distance of < 30 cm from the device with a strain relief in
order to protect the cable and/or the cable harness at the control connector against vibration.
6.9.1
Fixing points
INSTRUCTION
The housing has been designed for a maximum admissible torque of the fixing screws of 5 Nm! For
fixing the device, we recommend screws of the strength category 8.8, which are tightened with a
torque of 5 Nm.
1.
2 pcs. thread M5, stud hole with depth: = 15 mm
2.
4 pcs. thread M5, stud hole with depth: = 11 mm