55
Technical information
and start-up
BSC624-12V-B
8.5
Cooling system
INSTRUCTION
Ensure that no trapped air is present in the cooling system! The venting may also be implemented
via pressure or vacuum filling. Here, ensure that the admissible maximum system pressure is not
exceeded!
Trapped air in the cooling system may lead to an overheating of the device!
1.
Connection of cooling water input
(external Ø 16 mm)
2.
Connection of cooling water output
(external Ø 16 mm)
The cooling water hoses are to be implemented in accordance with the cooling water connection pieces
(external diameter 16 mm) in order to guarantee a water tight connection.
Ensure that the cooling water hoses are properly mounted onto the connection pieces in order to avoid leaks.
Please also ensure that the specified flow direction is adhered to.