VIBROCONTROL 1500
Operating the VIBROCONTROL 1500
- 40 -
VC1500EN / C103845.002 / V 09 / 14.04.2015
The trend course from the storage area 30 x 16 minutes cannot be displayed
at the equipment. This trend can be displayed only by the PC software
VIBROCONTROL 1500 Control-Center-software
. The trend 10 x 8 hours is
only present in the VIBROCONTROL 1500 instrument, and is in principle
differently formed than all other trends. Therefore it is not possible to find any
connection between this and other trends. This trend represents only 10
temporally last recorded measured values from the storage area 30 x 8
hours (see fig. 23).
The contents of all storage areas can be selected in unchanged form only
over the optionally available
VIBROCONTROL 1500 Control-Center-
Software
. Here the trends are actually displayed as trends over 30x16
minutes, 30 x 8 hours and 30 x 240 hours.
7.9
Rolling-element bearing condition and temperature -
Trend
The equipment also stores the trend of the rolling-element bearing condition
out of averaging of Avg-values as well as the temperature.
The operation is identical to the trend measurement with bearing vibration.
Select the following display from the menu and confirm the selection with
ENTER
.
Fig. 29: Rolling-element bearing condition and temperature trend.
A forecast computation is not possible for these measured values.