26
(7) Set only the backing paper (release paper) of a 62mm x 100mm roll into the machine
in the status of the VR spacer assembled as shown in Fig. 29. (Be sure to remove the
label.)
Make sure to set the backing paper so that the printed section (black sensor mark) on
the paper is aligned with the tray base.
62mmx100mm
2-3/7"x4"
202
62mmx100mm
2-3/7"x4"
202
62mmx100mm
2-3/7"x4"
202
Fig. 29
(8) If the value indicated in the “Results” column of the VR adjustment tool is in the range
of 218 to 222, the result is OK. (Refer to Fig. 30.) If it is out of the range and NG,
proceed to the next adjustment.
Fig. 30 “VR adjustment tool” screen
Backing paper
(release paper)
VR spacer
Tape sensor PCB ASSY
Tray base
* Align the side of the printed
section (black sensor mark) on
the backing paper with the tray
base.
The VR is normal if the
value is in the range of
218 to 222.