IV- 12
[ 10 ] The tape is fed, but the error message appears shortly.
* At this timing, implement "APPENDIX 1.
MAINTENANCE SOFTWARE OPERATION" again.
* At this timing, implement "APPENDIX 1.
MAINTENANCE SOFTWARE OPERATION" again.
* At this timing, implement "APPENDIX 1.
MAINTENANCE SOFTWARE OPERATION" again.
* At this timing, implement "APPENDIX 1.
MAINTENANCE SOFTWARE OPERATION" again.
Y
N
Y
N
The tape is fed, but the error
message appears shortly.
Is the VR adjustment
performed correctly?
* Refer to "APPENDIX 1.
MAINTENANCE SOFTWARE
OPERATION".
Y
N
Is the flat cable of the
tape sensor ASSY damaged?
Replace the tape sensor
PCB ASSY.
Replace the tape sensor
PCB ASSY.
Replace the main PCB ASSY.
Is the tape sensor ASSY
assembled onto the insert guide
correctly?
Y
N
Is the waveform of CN13
on the main PCB normal?
Correct the adjustment.
Re-assemble the tape sensor
ASSY correctly.