28
(11) After adjustment, attach a brand-new volume cover label onto the adjustment hole on
the upper cover ASSY. (Refer to Fig. 32.)
Fig. 32
(12) Click the “Quit VR adjustment” button. (Refer to Fig. 33.)
(13) Click the “Exit” button to finish the software.
(14) Turn off the power supply button of the machine.
This is the end of the adjustment.
Fig. 33 “VR adjustment tool” screen
Note: Be sure not to activate the maintenance software and P-Touch editor at the same
time. They do not work properly if they are activated at a time.
Brand-new volume cover label
Upper cover ASSY
Adjustment hole