24
APPENDIX 1.3
Role and Use Procedure of the VR Adjustment Tool
(QL1060NtstVRAdjust.exe)
[ 1 ] Role of the VR Adjustment Tool
This tool shows the VR value. Turn the VR adjustment volume according to the value
shown with the tool and adjust the VR.
Note: Always implement this adjustment if the main PCB ASSY or tape sensor PCB ASSY
is replaced, or if the result of the tape sensor inspection in the maintenance software
tool (QL1060NtstSE.exe) is NG.
[ 2 ] Use Procedure of the VR Adjustment Tool
(1) Connect the machine to your PC with the USB cable and turn the power supply button
ON.
Note: When new hardware is detected and the “New hardware detection wizard”
screen appears, press the “Cancel” button.
(2) Open the top cover ASSY of the machine.
(3) Start the VR adjustment tool. (File name: QL1060NtstVRAdjust.exe) (Refer to Fig. 26.)
(4) Click the “VR Adjustment” button so that the VR value appears in the “Results” column.
Write down the value in the column.
Fig. 26
“VR adjustment tool” screen
Start or finish VR adjustment.
Adjust the VR so that the value
is in the range of 218 to 222.