CHAPTER 6 TROUBLESHOOTING
6-8
Holding down the
–
switch and the
Set
switch at the same time while the error messages
display will cause the type of the error appears on the LCD display.
Error Messages
Meaning
Remedy
ERROR S01
Fatal error
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S02
Instruction access error
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S03
Memory address not
aligned
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S04
Instruction bus error
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S05
Data bus error
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S06
Privileged instruction
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S07
Breakpoint error
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S08
Illegal instruction
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S09
No fpu
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S10
Arithmetic overflow
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S11
Undefined Interrupt
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S12
Software 1 Interrupt
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR S13
Software 2 Interrupt
Turn off the printer. Wait a few seconds,
then turn it on again. If still remains,
replace the main PCB.
ERROR E41
Error in communication
with the engine controller
Turn off the printer. Wait a few seconds,
then turn it on again. Refer to
M-11 ‘E41
error’
in this chapter.