3-25
Confidential
(6) Remove the taptite cup S M3x6 screw, and lift the upper chute earth spring.
(7) Push the two hooks on the upper chute outward, and remove the cover open lever shaft
from the upper chute.
(8) Remove the upper chute earth spring from the upper chute.
(9) Remove the two taptite bind B M3x10 screws, and remove the double feeding sensor
holder from the upper chute.
(10) Release the double feeding sensor harness (Sent) from the securing fixture, and remove
the double feeding sensor (Sent) from the upper chute.
Fig. 3-22
HARNESS ROUTING: Refer to
.
Assembling Note:
• Attach the upper chute earth spring and the cover release lever spring on the position
described in the illustration above.
• Attach the upper chute earth spring under the cover open lever shaft.
Hook
Cover open lever shaft
Upper chute
earth spring
Double feeding sensor holder
Double feeding sensor (Sent)
Hook
Taptite bind B M3x10
Taptite cup S M3x6
Taptite bind B M3x10
Upper chute
Double feeding
sensor harness (Sent)
Cover release lever spring
Summary of Contents for ADS-2000e
Page 15: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 22: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 28: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 50: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 54: ...3 2 Confidential 2 PACKING ...
Page 93: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 107: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 113: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 116: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 117: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 119: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 123: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...