Brocade Adapters Administrator’s Guide
55
53-1001256-01
Master Log
5
Master Log
The Master Log Properties dialog box, described in
Table 10
, displays a list of all events that have
occurred. Event monitoring enables early fault detection and isolation on a selected adapter. You
can filter the events based on the user-defined criteria shown in
Figure 22
.
Event severities
Table 11
describes the icons that represent the four event types.
TABLE 10
Master Log fields
Field
Description
Filter button
Click to launch the Master Log Filter dialog box.
Clear Filter button
Click to clear the master log filter option set.
Sr No column
Displays a numbering sequence in ascending order.
Severity column
Displays the event severity (informational, minor, major, or critical).
WWN/MAC column
Displays the world wide name (WWN) or the media access control
(MAC) address of the device on which the event occurred.
Category column
Displays the category of event; for example, Rport or ITNIM.
Subcategory column
Displays the subcategory of the main category.
Description column
Displays a brief description of the event.
Date/Time column
Displays the date and time when the event occurred.
TABLE 11
HCM Master Log icons
Description
Critical-level messages indicate that the software has detected serious problems that will eventually cause a
partial or complete failure of a subsystem if not corrected immediately; for example, a power supply failure or
rise in temperature must receive immediate attention.
Major messages represent conditions that do not impact overall system functionality significantly. For
example, timeouts on certain operations, failures of certain operations after retries, invalid parameters, or
failure to perform a requested operation.
Minor messages highlight a current operating condition that should be checked or it might lead to a failure in
the future. For example, a power supply failure in a redundant system relays a warning that the system is no
longer operating in redundant mode and that the failed power supply needs to be replaced or fixed.
Information-level messages report the current non-error status of the system components; for example, the
online and offline status of a fabric port.
Summary of Contents for 415
Page 10: ...x Brocade Adapters Administrator s Guide 53 1001256 01 ...
Page 12: ...xii Brocade Adapters Administrator s Guide 53 1001256 01 ...
Page 18: ...xviii Brocade Adapters Administrator s Guide 53 1001256 01 ...
Page 38: ...20 Brocade Adapters Administrator s Guide 53 1001256 01 Logging off HCM 3 ...
Page 70: ...52 Brocade Adapters Administrator s Guide 53 1001256 01 VLAN configuration 4 ...
Page 78: ...60 Brocade Adapters Administrator s Guide 53 1001256 01 Syslog support 5 ...
Page 218: ...200 Brocade Adapters Administrator s Guide 53 1001256 01 HCM tab navigation C ...