8 - VENTILATION SYSTEM
8-1
AIR FILTER REPLACEMENT
Note:
Replace every
3 Months
or sooner if
needed.
1. Open access door.
2. Unlatch
filter
tray and pull tray out
(about 1.50”) with your free hand
under the tray and swing tray down
45
°.
3. With both hands pull tray out towards
you.
4. Remove Air filter.
5. Install new Air Filter in tray with arrows
up as shown in picture at right.
6. Reinstall filter tray into unit by tilting it
at 45
° and sliding it into the cabinet
as far as it will go at the 45° tilt.
7. While lifting latch end up, push filter
back with your thumbs toward the
back of the tray until it stops. Also
when the top of the filter is against the
top of the cabinet and push tray in
until it stops.
8. Latch in place and close access door.
9. Unit is ready to operate.
broaster.com Manual # 16421 5/06 Rev 10/17