OPERATIONAL LOCKOUTS
Indicator lights illuminate to show “Opera
-
tion Lockout” conditions that need to be
corrected before unit will function.
15.
Product Door Indicator Light:
Illumi
-
nates when the Product Door is open.
16.
Access Door Indicator Light:
Illumi
-
nates when the Access Door is open
or when Access Door Latch is improp
-
erly latched.
17.
Element Up Indicator Light:
Illumi
-
nates when the heating element is in
the raised position.
18.
Air Flow Indicator Light:
Illuminates
when the flow of air through the Air Fil
-
ter area falls below acceptable level.
Replace Air Filter every 3
months.
19.
Air Filter Indicator Light:
Illuminates
when the air filter is not installed in the
unit.
20.
Grease Filter Indicator Light:
Illumi
-
nates when the grease filter is not
installed in the unit.
21.
Hi-Limit Control Indicator Light:
Prevents oil temperature from exceed
-
ing 475° F. If power to control turns off
due to Hi-Limit Control, this indicator
light will illuminate, press the OFF but
-
ton and
DO NOT
attempt to operate
until it has been serviced by an autho
-
rized Broaster Company representa
-
tive.
22.
Fire System Light:
Illuminates when
6 months have passed to indicate
semi-annual maintenance is due on
fire suppression system.
CONTROLLER BASIC
PROGRAMMING
NORMAL OPERATING MODE
Check oil level before
pressing the ‘ON’ button.
Action:
Press ‘ON’ button.
Response:
Temp Display alternates
between number values for cook tempera
-
ture, and LO (idle mode). LO will disappear
when oil temperature has reached cook
temperature value. Time Display will show
the set time in minutes and seconds.
Set Temperature:
Action:
Press Cook Temperature But
-
ton twice within 5 seconds.
Response:
Programming mode has
been entered. Flashing Temp Display reads
“###F.” (### = temperature value ie: 360F)
Action:
If desired, press keypad num
-
bers to change displayed value then press
Cook Temperature Button once to enter
new value into memory.
Response:
Controller returns to idle
mode.
Set Time:
Action:
Press Cook Time Button twice
within 5 seconds.
Response:
Programming mode has
been entered. Flashing Time Display reads
“##:##.” (##:## = time value ie: 08:00)
Action:
If desired, press key pad num
-
bers to change displayed value in minutes
and seconds then press Cook Time Button
once to enter new value into memory.
Response:
Controller returns to idle
mode.
broaster.com Manual #16421 10/20 Rev 10/20
Summary of Contents for VF-2
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ......
Page 30: ......
Page 34: ......
Page 36: ......
Page 54: ......
Page 58: ......
Page 62: ......
Page 64: ......
Page 68: ......
Page 69: ......
Page 70: ...Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...