Airplane Maintenance Manual
Bristell
B23
Chapter 21
Chapter 21 Page 4
Issue: 30-Sep-2020
(7) is located, which splits hot air flow into the canopy bubble outlet
(1) and into the crew legs outlet (8). The mixture flap is controlled by
the MIXTURE knob (9).
Fig. 3
Heating System
Item
Description
Item Description
1
Canopy bubble outlet
2
Air hose
3
Air inlet
4
Heat exchanger
5
Muffler
6
Heating flap
7
Mixture flap
8
Crew legs outlet
9
Mixture knob
10
Heating knob
21-40-01 Control Knobs
Removal
Tools needed:
wrench size
½ in
, 9/16 in
pliers, cutting pliers
See Fig. 4