background image

 

 

SECTION 2. 

 

PREPARATION AND INSPECTION

 

2.1 PERSONNEL TRAINING

 

 

The aerial platform is a personnel transport device.

 

Therefore, it is to be used and maintained exclusively by trained and 

qualified personnel. Use of the machine is not permitted by persons 

under the influence of alcohol or drugs or those subject to attacks of 

epilepsy, vertigo or loss of physical control.

 

 

Operator training must include what follows:

 

 

1.

 

Use and limits of the commands from the platform, from the 

ground and emergency commands as well as safety systems.

 

2.

 

Command and control signage, instructions and warnings at-

tached to the machine.

 

3.

 

Regulations defined by the employer and by government regu-

lation.

 

4.

 

Use of the approved anti

-

fall protection device, when needed.

 

5.

 

Sufficient knowledge of the mechanical function of the ma-

chine to recognise a true or potential malfunction or break-

down. 

 

6.

 

Safe methods for the use of the machine when encountering 

super

-

elevated obstacles, other equipment or obstacles in 

movement, dips, holes and inclined descents. 

 

7.

 

Methods for the avoidance of hazards from unprotected elec-

trical conductors.

 

8.

 

Requirements for a particular job or a particular application of 

the machine.

 

 

Training supervision

 

Training must be given under the supervision of a qualified person, in 

an open area, free of obstacles.  It must continue until the trainee is 

capable of using the machine safely.

 

 

Operator responsibility

 

The operator must be instructed regarding the responsibility and the 

authority to turn off the machine in case of malfunction or breakdown or 

in the presence of other unsafe conditions, relative to both the machine 

and the workplace.

 

NOTE: 

The manufacturer or the distributor must make qualified person-

nel  available  for  training  both  at  the  time  of  delivery  of 

 

the  first  units  and  afterwards,  if  requested  by  the  end  user 

 

or the by assigned personnel.

 

2.2 PREPARATION INSPECTION AND MAINTENANCE

 

 

 

BRAVIISOL provides information relative to machine inspection, indicated in 

the following table 2.3.

 

For further information regarding the aerial work platforms, consult local 

regulations. 

 

The frequency of inspections and maintenance procedures must increase 

according to necessity: when the machine is used under adverse environ-

mental conditions, with greater frequency or for difficult or particularly de-

manding jobs.

 

 

2.3 PRELIMINARY INSPECTIONS BEFORE START UP

 

The inspection prior to use includes the following operations:

 

 

1.

Cleaning –

 

Verify and check for any eventual leaks (oil, hydraulic fluid or 

battery acid) or for foreign objects on any of the surfaces. 

 

Warn maintenance personnel of any apparent leaks.

 

 

2. Signs and adhesive stickers –

 

Check and verify that these are all clean 

and legible. 

 

Check that no sign or adhesive sticker is missing. 

 

Make sure that any sign or adhesive sticker that is not legible is cleaned 

or substituted. 

(See "Application of the adhesive

 

stickers" in Section 3)

.

 

 

3. Use and safety manuals –

 

make sure that the following manuals are 

present in the weather resistant compartment (PIC. 2.A): 

 

Use and Safety Manual, 

 

 

4. Outline of complete daily inspection –

 

(See Section 2.4).

 

 

5. Battery –

 

Charge as needed (See Section 3.5).

 

 

6. Hydraulic oil –

 

The level of the hydraulic oil in the reservoir can vary 

according to the temperature of the oil.  That is, in a cold machine, it is pos-

sible that the Oil level will not reach the FULL mark on the dip stick. 

 

Lift and lower the elevator several times to obtain a more precise reading of 

the level on the dip stick. 

 

When the hydraulic oil is heated up, verify the reading on the dip stick, 

which should indicate a level equal or near the FULL mark.

 

• 

DO NOT FILL BEYOND THE FULL MARK.

 

• 

ALWAYS TOP UP the oil if its level is below the mark 

-

 ADD.

 

12

 

13

 

2.A 

Summary of Contents for Sprint LUI MINI P.A.

Page 1: ...aviisol Divisione Meccanica s r l S S 16 Adriatica km 314 600 60022 Castelfidardo AN Italy Tel 0039 071 7819090 Fax 0039 071 7819355 www bravi platforms com www bravi parts com Order truck model LUI P...

Page 2: ...OR ORANGE BACKGROUND THIS PRODUCT MUST CONFORM TO ALL OF THE PROCEDURES REGARDING SAFETY INDICATED IN THE TECHNICAL BULLETINS FOR INFORMATION ON EVENTUAL TECHNICAL BULLETINS REGARDING THE SAFETY OF B...

Page 3: ...cipated by BRAVIISOL DIVISIONE MECCANICA S R L All operational personnel must become familiar with the commands con trols and emergency functions of the machine specified in the manual Carefully read...

Page 4: ...mely corrosive Make sure that it does not come into contact with the skin or clothing Charge the batteries in a well ventilated area SECTION 1 SAFETY PRECAUTIONS 1 4 RISK OF FALLING Before using the m...

Page 5: ...ar or soft surface Before driving onto floors bridges trucks or other surfaces verify the maximum load bearing values of those Do not exceed the maximum load of the elevated platform Distribute cargo...

Page 6: ...llide with the operational commands or the person on the platform or that they interfere with the same Make sure that the operators of other machines that are elevated or on ground level are informed...

Page 7: ...the time of delivery of the first units and afterwards if requested by the end user or the by assigned personnel 2 2 PREPARATION INSPECTION AND MAINTENANCE BRAVIISOL provides information relative to...

Page 8: ...IISOL D M SRL has no direct control over the utilisa tion of the machine Utilisation of the machine according to safety regulations is the responsibility of the end user It is the responsibility of th...

Page 9: ...mand panel in the basket and the one on the chassis control panel Check and verify by testing the proper operation of the manual descending emergency lever 2 6 FUNCTIONAL VERIFICATIONS At the end of t...

Page 10: ...nd programmable command station panel when the machine is being serviced or functional verifications are per formed or in case of emergency if the operator on the platform is not capa ble of lowering...

Page 11: ...osi tion extended outward For LUI PKI the LCD screen on which the status of the machine may be visualised on the ground command panel must indicate normal operational conditions upon turn on of the ma...

Page 12: ...ies automatically when they have reached full charge NOTE When the battery charger is connected to an AC electrical outlet the platform vehicle transmission is disabled THE LEAD ACID BATTERIES MAY GEN...

Page 13: ...on the cord so as to not damage it NOTE When green LED is on the battery charger is switched off automatically A A C POWER INPUT B CHARGE STATUS WARN ING LIGHT FOR THE BAT TERY CHARGER B A A B LUI PK...

Page 14: ...he RESET position Left and Right sensor for activating the functions Left and Right hand must be placed on the handles in front of the sensor to allow the activation of the driving raise lower functio...

Page 15: ...elevator group using the relative buttons on the machine Push and hold down the upper button Button 8 section 3 6 to activate the electrical lifting of the cargo platform Release of the button automat...

Page 16: ...IN A STRAIGHT LINE POSITION THE VEHICLE IN THE DIRECTION DESIRED AND MOVE BACKWARDS OR FOR WARDS ONLY ACTIVATING THE THROTTLE HANDLE Footswitches DO NOT PLACE THE FOOT ON THE FOOT SWITCHES BEFORE TURN...

Page 17: ...ieve greater heights at which to work In addition he or she must never lean out or extend him her self outside of the railing of the platform basket Before activating the machine verify that the machi...

Page 18: ...rtically on the front part of the elevator group using the relative lever underneath the cargo shelf Push and hold the lever 6 and lift up with both hands the cargo shelf for raise the cargo platform...

Page 19: ...ases of the machine Reset DOES NOT actuate the machine but enable the command devices Display for LUI PKI This is the principle control display system on LUI PKI It visualises useful information on th...

Page 20: ...y depleted in the machine it is not possible to manually release the brakes RELEASE THE BRAKES MANUALLY ONLY IF THE MACHINE IS ON A HORIZONTAL SURFACE AND IT IS COMPLETELY LOCKED The operator MUST mak...

Page 21: ...D is on the raising of the basket is not allowed and the bat tery need to be charged NOTE SWITCHING OFF THE MACHINE WHEN NOT IN USE WOULD INCREASE THE BATTERY LIFE 6a 6b 7 Basket Control Station LUI P...

Page 22: ...During the following operations and after having performed all of the procedures for the emergency descent the operator must pay great attention to leaving the area and making sure that no other pers...

Page 23: ...a standard fork lift NOTE The fork lift truck must be capable of sustaining the gross weight of the machine See the operational technical specifications of the machine at the beginning of the section...

Page 24: ...stood the safety indications in the front of this manual See PART 2 Who possess personal safety equipment and use it as needed and with the machine at a zero energy condition key switch turned to zero...

Page 25: ...48 49 SECTION 5 GENERAL TECHNICAL SPECIFI CATIONS AND OPERATOR MAINTENANCE...

Page 26: ...50 51 SECTION 5 GENERAL TECHNICAL SPECIFI CATIONS AND OPERATOR MAINTENANCE...

Page 27: ...ERO Maximum Slope Practicable EXCLUSIVELY WITH PLATFORM COMPLETELY LOW ERED 35 Platform Cycle Performance Raising 18 sec Lowering 15 sec Drive System Two Hand Proportional Tyres Anti Skid Solid Rubber...

Page 28: ...UPPLY Batteries N 01 12V 85Ah 20hr POWER SUPPLY 12 V c c Recharge lines power supply 110 V AC 60Hz 220 V AC 50 Hz NOISE LEVELS Less than 70 dB A Operational height 416 cm Platform Height Elevator Comp...

Page 29: ...al connectors and clean them with a rag wet with water If the oxidation layer is particularly thick brush off the top layer and clean them with a rag wet with water 5 2 Weight of the Machine Component...

Page 30: ...of the machine As the machine works in presence of dusts it must be daily or whenever it would be necessary clean it With a cloth slightly moistened clean the control panels the walking surface of th...

Page 31: ...y in their respective positions and that there are no visible leaks signs of excessive wear or damaged areas Check and verify that there are no wires or cables that have come loose and hang from the u...

Page 32: ...HIGH CHECK LINE CONT 3 3 FAULT VALVE FEEDBACK HIGH CHECK VALVE WIRING 3 2 FUNCTIONS LOCKED BATTERY 4 4 FAULT BAD INTERNAL 12V 4 3 FAULT BAD 5V JOYSTICK SUPPLY CHECK P15 12 WIRING 4 5 DECRIPTION ERROR...

Page 33: ...SECTION 7 7 2 HYDRAULIC SCHEME LUI PKI 6 6 64 65...

Page 34: ...SECTION 7 7 3 HYDRAULIC SCHEME LUI MINI P A 66 67...

Page 35: ...SECTION 7 7 4 WIRING DIAGRAM LUI PKI 68 69...

Page 36: ...witch input B active Elevation Switch P12 10 Analog Input P12 11 Analog Input P12 12 Analog Input P15 1 switch input B active Platform Mode P15 2 switch input B active P15 3 switch input B active P15...

Page 37: ...LSUP NORMALLY CLOSED LIMIT SWITCH RAISED BASKET EMSB BASKET EMERGENCY BUTTON RM PUMP RELAY LSDW NORMALLY CLOSED LIMIT SWITCH LOWERED BASKET PLB LOWERPUSH BUTTON BASKET POSITION PRB RAISE PUSH BUTTON B...

Page 38: ...t without being agreed upon in writing in advance with the manufacturer 3 Labor on consumable items such as tire batteries 4 Any indirect incidental consequential or special damage including without l...

Page 39: ...OL Divisione Meccanica S r l S S 16 Adriatica km 314 600 60022 Castelfidardo AN Tel 071 7819090 Fax 071 7819355 E mail info bravi platforms com Website www bravi platforms com Spare parts www bravi pa...

Reviews: