NOTE:
Check the level of the hydraulic oil
with the ma-
chine having the basket lowered,
from the sight
glass found under the cover. If necessary, top up
with a mineral oil with a viscosity index of 22 (for
climactic conditions with very cold temperatures,
that is, below
-
20°C, the use of mineral oil with a
lower freezing point , about –
45
°C, is rec-
ommended.
Attention Pollution Hazard
Do not dispose of the oil into the environ-
ment.
TABLE 2.3
2.4 COMPLETE DAILY INSPECTION
TO AVOID POSSIBLE INJURIES, MAKE SURE THAT THE ELECTRICAL
POWER SUPPLY OF THE MACHINE IS TURNED OFF DURING THE IN-
SPECTION. DO NOT USE THE MACHINE BEFORE ANY AND ALL MAL-
FUNCTIONS HAVE BEEN REPAIRED.
DO NOT NEGLECT THE VISUAL INSPECTION OF THE LOWER PART OF
THE BASE FRAME.
CHECK AND VERIFY THAT THERE ARE NO FOREIGN OBJECTS OR DE-
BRIS THAT COULD CAUSE SERIOUS DAMAGE TO THE MACHINE.
The operator must not accept the responsibility of operating the machine until
this manual has been read and understood in each of its parts and a first test
-
drive of the vehicle has been taken under the supervision of a qualified expert
operator.
Only authorised personnel and qualified operators may operate this machine.
This manual and its attachments must be considered an integral part of this ma-
chine and must remain with the machine at all times.
The manufacturer, BRAVIISOL D.M. SRL, has no direct control over the utilisa-
tion of the machine.
Utilisation of the machine according to safety regulations is the responsibility of
the end user.
It is the responsibility of the operator to make a thorough inspection of the ma-
chine before each use.
The purpose of the complete daily inspection is to check and verify that the ma-
chine is in order, to ascertain the absence of anomalies, faults or malfunctions
and to determine if routine maintenance is required. If any damage or unauthor-
ised changes to the machine, with respect to how it was delivered, are found,
immediately tag it as such and DO NOT USE IT.
TYPE
FREQUENCY
MAIN RESPON-
SABILITY
QUALIFICATION
FOR SERVICE
REFERENCE
PRELIMINARY
INSPECTION
FOR START
UP
Before each day of
work, or else at
each change of
operator.
User or operator
User or operator
Safety and Use Man-
ual page 59, 60 and
relative Inspection
Forms
PERIODIC
INSPECTION
At an interval of 3
months or 150
hours, according to
the circumstances,
or else if the ma-
chine has not been
used for over 3
months or else if it
has been pur-
chased used.
Owner, conces-
sionary or user.
BRAVI Qualified
Mechanic
Safety and Use Man-
ual page 57, 58, Ser-
vice and Maintenance
Manual and relative
Inspection Forms
ANNUAL
INSPECTION
Annual, within 13
months from the
last inspection
Owner, conces-
sionary or user.
BRAVI Qualified
Mechanic
Safety and Use Man-
ual page 61 Service
and Maintenance
Manual and relative
Inspection Forms
WARNING
WARNING
WARNING
14
15
SECTION 2.
PREPARATION AND INSPECTION
Summary of Contents for Sprint LUI MINI P.A.
Page 25: ...48 49 SECTION 5 GENERAL TECHNICAL SPECIFI CATIONS AND OPERATOR MAINTENANCE...
Page 26: ...50 51 SECTION 5 GENERAL TECHNICAL SPECIFI CATIONS AND OPERATOR MAINTENANCE...
Page 33: ...SECTION 7 7 2 HYDRAULIC SCHEME LUI PKI 6 6 64 65...
Page 34: ...SECTION 7 7 3 HYDRAULIC SCHEME LUI MINI P A 66 67...