background image

 

 

3.4 BOOT 

-

 (TRANSPORT PLATFORM)

 

 

 

Removal

 

 

1. 

Lift the boot in correspondence to the back part (column) so as to 

free bumper on the base frame. Therefore have the boot slide forward 

while lifting it to completely detach the boot from the vehicle.

 

 

Installation

 

 

1. 

Position the boot on its relative bumper on the upper part of the 

frame and have it slide backwards.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE BOOT (TRANSPORT PLATFORM) MUST BE USED EXCLU-

SIVELY FOR CARGO MATERIALS. 

 

PREVENT TRANSIT OF PERSONNEL ON THE TRANSPORT PLAT-

FORM BOOT.

 

Boot Right   
Side - Cargo Lift Plat-
form 

3.5 BATTERY CHARGING

 

 

Battery low voltage alarm warning light

 

 

On the LUI PKI command panels on the platform and the ground station 

have indicators of low battery voltage.

 

On LUI MINI P.A. frame section has the indicator of low battery voltage.

 

 

Battery charging procedure

 

This machine is equipped with a battery charger with an AC electrical power 

input/DC electrical power output.  The battery charger stops charging the 

batteries automatically when they have reached full charge.

 

 

NOTE: 

When the battery charger is connected to an AC electrical outlet, the 

platform vehicle transmission is disabled.

 

 

 

 

 

 

 

THE LEAD ACID BATTERIES MAY GENERATE EXPLOSIVE HYDROGEN 

GAS DURING NORMAL OPERATION.  KEEP SPARKS, OPEN FLAMES 

OR LIT TOBACCO AT A SAFE DISTANCE FROM THE BATTERIES.  

DURING BATTERY CHARGING PROVIDE FOR ADEQUATE VENTILA-

TION IN THE AREA.  DO NOT CHARGE A FROZEN BATTERY.  CARE-

FULLY STUDY THE PRECAUTIONS SPECIFIED BY THE BATTERY 

MANUFACTURER RELATIVE TO THE SPEED OF CHARGING RECOM-

MENDED AS WELL AS THE POSSIBILITY OF REMOVAL OF THE 

CELL CAPS DURING CHARGING.

 

 

 

1.

 

Park the vehicle in a well ventilated area near an AC wall socket.

 

2.

 

Always use a grounded (earthed) AC socket.  Connect the bat-

tery charger to a correctly installed AC socket with ground connection 

according to all of the local regulations in force.  The grounded socket 

is necessary so as to reduce the risk of electrical shocks 

-

 do not use 

grounded adapters and do not modify the plug.  If an extension is 

used, avoid excessive drops in voltage by using the 3 wire 12 AWG 

type.

 

ATTENTION

 

22

 

23

 

SECTION 3. 

 

OPERATION OF THE MACHINE

 

Summary of Contents for Sprint LUI MINI P.A.

Page 1: ...aviisol Divisione Meccanica s r l S S 16 Adriatica km 314 600 60022 Castelfidardo AN Italy Tel 0039 071 7819090 Fax 0039 071 7819355 www bravi platforms com www bravi parts com Order truck model LUI P...

Page 2: ...OR ORANGE BACKGROUND THIS PRODUCT MUST CONFORM TO ALL OF THE PROCEDURES REGARDING SAFETY INDICATED IN THE TECHNICAL BULLETINS FOR INFORMATION ON EVENTUAL TECHNICAL BULLETINS REGARDING THE SAFETY OF B...

Page 3: ...cipated by BRAVIISOL DIVISIONE MECCANICA S R L All operational personnel must become familiar with the commands con trols and emergency functions of the machine specified in the manual Carefully read...

Page 4: ...mely corrosive Make sure that it does not come into contact with the skin or clothing Charge the batteries in a well ventilated area SECTION 1 SAFETY PRECAUTIONS 1 4 RISK OF FALLING Before using the m...

Page 5: ...ar or soft surface Before driving onto floors bridges trucks or other surfaces verify the maximum load bearing values of those Do not exceed the maximum load of the elevated platform Distribute cargo...

Page 6: ...llide with the operational commands or the person on the platform or that they interfere with the same Make sure that the operators of other machines that are elevated or on ground level are informed...

Page 7: ...the time of delivery of the first units and afterwards if requested by the end user or the by assigned personnel 2 2 PREPARATION INSPECTION AND MAINTENANCE BRAVIISOL provides information relative to...

Page 8: ...IISOL D M SRL has no direct control over the utilisa tion of the machine Utilisation of the machine according to safety regulations is the responsibility of the end user It is the responsibility of th...

Page 9: ...mand panel in the basket and the one on the chassis control panel Check and verify by testing the proper operation of the manual descending emergency lever 2 6 FUNCTIONAL VERIFICATIONS At the end of t...

Page 10: ...nd programmable command station panel when the machine is being serviced or functional verifications are per formed or in case of emergency if the operator on the platform is not capa ble of lowering...

Page 11: ...osi tion extended outward For LUI PKI the LCD screen on which the status of the machine may be visualised on the ground command panel must indicate normal operational conditions upon turn on of the ma...

Page 12: ...ies automatically when they have reached full charge NOTE When the battery charger is connected to an AC electrical outlet the platform vehicle transmission is disabled THE LEAD ACID BATTERIES MAY GEN...

Page 13: ...on the cord so as to not damage it NOTE When green LED is on the battery charger is switched off automatically A A C POWER INPUT B CHARGE STATUS WARN ING LIGHT FOR THE BAT TERY CHARGER B A A B LUI PK...

Page 14: ...he RESET position Left and Right sensor for activating the functions Left and Right hand must be placed on the handles in front of the sensor to allow the activation of the driving raise lower functio...

Page 15: ...elevator group using the relative buttons on the machine Push and hold down the upper button Button 8 section 3 6 to activate the electrical lifting of the cargo platform Release of the button automat...

Page 16: ...IN A STRAIGHT LINE POSITION THE VEHICLE IN THE DIRECTION DESIRED AND MOVE BACKWARDS OR FOR WARDS ONLY ACTIVATING THE THROTTLE HANDLE Footswitches DO NOT PLACE THE FOOT ON THE FOOT SWITCHES BEFORE TURN...

Page 17: ...ieve greater heights at which to work In addition he or she must never lean out or extend him her self outside of the railing of the platform basket Before activating the machine verify that the machi...

Page 18: ...rtically on the front part of the elevator group using the relative lever underneath the cargo shelf Push and hold the lever 6 and lift up with both hands the cargo shelf for raise the cargo platform...

Page 19: ...ases of the machine Reset DOES NOT actuate the machine but enable the command devices Display for LUI PKI This is the principle control display system on LUI PKI It visualises useful information on th...

Page 20: ...y depleted in the machine it is not possible to manually release the brakes RELEASE THE BRAKES MANUALLY ONLY IF THE MACHINE IS ON A HORIZONTAL SURFACE AND IT IS COMPLETELY LOCKED The operator MUST mak...

Page 21: ...D is on the raising of the basket is not allowed and the bat tery need to be charged NOTE SWITCHING OFF THE MACHINE WHEN NOT IN USE WOULD INCREASE THE BATTERY LIFE 6a 6b 7 Basket Control Station LUI P...

Page 22: ...During the following operations and after having performed all of the procedures for the emergency descent the operator must pay great attention to leaving the area and making sure that no other pers...

Page 23: ...a standard fork lift NOTE The fork lift truck must be capable of sustaining the gross weight of the machine See the operational technical specifications of the machine at the beginning of the section...

Page 24: ...stood the safety indications in the front of this manual See PART 2 Who possess personal safety equipment and use it as needed and with the machine at a zero energy condition key switch turned to zero...

Page 25: ...48 49 SECTION 5 GENERAL TECHNICAL SPECIFI CATIONS AND OPERATOR MAINTENANCE...

Page 26: ...50 51 SECTION 5 GENERAL TECHNICAL SPECIFI CATIONS AND OPERATOR MAINTENANCE...

Page 27: ...ERO Maximum Slope Practicable EXCLUSIVELY WITH PLATFORM COMPLETELY LOW ERED 35 Platform Cycle Performance Raising 18 sec Lowering 15 sec Drive System Two Hand Proportional Tyres Anti Skid Solid Rubber...

Page 28: ...UPPLY Batteries N 01 12V 85Ah 20hr POWER SUPPLY 12 V c c Recharge lines power supply 110 V AC 60Hz 220 V AC 50 Hz NOISE LEVELS Less than 70 dB A Operational height 416 cm Platform Height Elevator Comp...

Page 29: ...al connectors and clean them with a rag wet with water If the oxidation layer is particularly thick brush off the top layer and clean them with a rag wet with water 5 2 Weight of the Machine Component...

Page 30: ...of the machine As the machine works in presence of dusts it must be daily or whenever it would be necessary clean it With a cloth slightly moistened clean the control panels the walking surface of th...

Page 31: ...y in their respective positions and that there are no visible leaks signs of excessive wear or damaged areas Check and verify that there are no wires or cables that have come loose and hang from the u...

Page 32: ...HIGH CHECK LINE CONT 3 3 FAULT VALVE FEEDBACK HIGH CHECK VALVE WIRING 3 2 FUNCTIONS LOCKED BATTERY 4 4 FAULT BAD INTERNAL 12V 4 3 FAULT BAD 5V JOYSTICK SUPPLY CHECK P15 12 WIRING 4 5 DECRIPTION ERROR...

Page 33: ...SECTION 7 7 2 HYDRAULIC SCHEME LUI PKI 6 6 64 65...

Page 34: ...SECTION 7 7 3 HYDRAULIC SCHEME LUI MINI P A 66 67...

Page 35: ...SECTION 7 7 4 WIRING DIAGRAM LUI PKI 68 69...

Page 36: ...witch input B active Elevation Switch P12 10 Analog Input P12 11 Analog Input P12 12 Analog Input P15 1 switch input B active Platform Mode P15 2 switch input B active P15 3 switch input B active P15...

Page 37: ...LSUP NORMALLY CLOSED LIMIT SWITCH RAISED BASKET EMSB BASKET EMERGENCY BUTTON RM PUMP RELAY LSDW NORMALLY CLOSED LIMIT SWITCH LOWERED BASKET PLB LOWERPUSH BUTTON BASKET POSITION PRB RAISE PUSH BUTTON B...

Page 38: ...t without being agreed upon in writing in advance with the manufacturer 3 Labor on consumable items such as tire batteries 4 Any indirect incidental consequential or special damage including without l...

Page 39: ...OL Divisione Meccanica S r l S S 16 Adriatica km 314 600 60022 Castelfidardo AN Tel 071 7819090 Fax 071 7819355 E mail info bravi platforms com Website www bravi platforms com Spare parts www bravi pa...