I E16x442 Rev: 00
Page 37 of 73
7.
Programming of the Monitors
7.1.
Programming of the Monitors via Front Keyboard
Principle:
Select a parameter via its ‚name’
Pgg.ss
,
in that
gg
: Parameter-group number and
ss
: Step-number within the group,
then display the value and alter if required.
Procedure:
Initiate programming phase by pressing keys
and
together; instead of the normal display P00.00. appears
Select the group or step number with keys
,
.
Switch between Groups and Step Fields with the
. key
Current value of the Parameters is displayed with key
.
Select active position with the
. key
Adjust the number in the active field with keys
,
.
Acknowledge and set with key
, Discard (original value remains) with key
.
Return to operational mode with the
key. The display then returns to the cur
rent ‘is’ speed (with E1665) resp.
to the current test-speed (with E1697)
See example below: Change parameter P01.01 from 2386 to 2387 or 2385.
Move
active
digit with
Normal
Display While Programming
Display
active digit(s) blinking (shown underlined here)
Select
Select
Change
Toggle
Group
Toggle
Step-No.
Toggle
Parameter Value
with
with
with
key(s)
Key
Key
+
P
P
E
E
E
: Enter
or
: Cancel
P
Enter : new, changed value is valid
Cancel : original value still valid
P
P