Parameter Group P07.xx of Monitor E1665
Trip-Line-Monitoring, Rotational Direction Output
Parameter No.
Meaning of Parameter
Setting Range of Parameter
Description of Parameters and their Settings
P07.00
Trip-Line-Monitoring
Range: 0 .. 1
If activated the Monitor checks the output of the Trip-Lines.
If two or three Trip-Lines indicate trip condition the monitor moves to trip sta-
tus (Trip Lock Function).
Following the reset signal the monitor releases the trip state for one second.
Within this time the feedback signal must respond correctly, otherwise the
monitor returns to trip status.
Setting
0 : Trip-Line-Monitoring not active
1 : Trip-Line-Monitoring active, with response time until trip = 50 msec
2 : Trip-Line-Monitoring active, with response time until trip = 3 msec
P07.01
Trip-Line Level at Trip-Status
Range: 0 .. 1
Setting
0 : Low Level at Trip-Status (relays de-energized to Trip)
1 : High-Level at Trip-Status (relays energized to Trip)
P07.02
Signal-Input Level for Rotation-
al Direction Detection
Range: 0 .. 1
Setting
0 : Signal level low is assigned to forward motion
1 : Signal level high is assigned to forward motion
P07.03
Relay State for status forward
motion
Range: 0 .. 1
Setting
0 : Relay de-energized at status forward motion
1 : Relay energized at status forward motion
P07.04
Reserved for future application.
Fix value 0