73
H:Parameter reserved
Initial value
:
n. 00 00
(
H L
)
Control mode
:
Origin mode
Unit
:
~
Setting range
:
~
Modify effective time
:
“●”can be modified at any time, and will take effect by power off and
restart.
Parameter function
:
The same as P5-10.L
◎
P5-21
L:/COIN Positioning finish
H:/V-CMP Synchronous speed detection
0X0514
Initial value
:
n. 00 01
(
H L
)
Control mode
:
~
Unit
:
~
Setting range
:
Modify effective time
:
“●”can be modified at any time, and will take effect by power off and
restart.
Parameter function
:
L:00: No output to terminal 01: Output positive signal from SO1 terminal
02: Output positive signal from SO2 terminal 03: Output positive signal from SO3 terminal
03: Output positive signal from SO3 terminal 04: Output positive signal from SO4 terminal
81: Output reverse signal from SO1 terminal 82: Output reverse signal from SO2 terminal
83: Output reverse signal from SO3 terminal 84: Output reverse signal from SO4 terminal
H
:
The same as P5-21.L
◎
P5-22
L:/TGON Rotation detection H:/S-RDY Ready
0X0515
Initial value
:
n. 00 00
(
H L
)
Control mode
:
~
Unit
:
~
Setting range
:
~
Modify effective time
:
“●”can be modified at any time, and will take effect by power off and
restart.
Parameter function
:
The same as P5-21.L
◎
P5-23
L:/CLT Torque H:/VLT Speed limit detection
0X0516