main switch and the Stand-by button located on the right side of the display.
4
This will start the update procedure of the firmware present on the USB key.
Wait for the files to be completely loaded and verified.
5
When updating the display board, follow the instructions provided on the screen in order to proceed with the calibration on the
touch display.
6
At the end of the procedure the company logo is shown on the display and the machine is ready to operated as usually.
14 CALIBRATION OF THE TOUCH DISPLAY
It is possible to execute the calibration procedure of the touch display starting the dispenser by simultaneously actuating the main
switch and pressing any point of the touch display.
Then follow he instructions provided on the screen.
At the of the procedure the company logo is shown on the display and the machine is ready to operated as usually.