29
a maintenance password (default value: 1234), however, you can access the entire list of parameters (PA00 - PA28).
figure 4
The icons 1-7 have the following meanings :
Select the individual parameter and press icon 5 to enter the edit mode.
figure 5
The icons 1-4 have the following meanings :
The complete list of parameters and respective functions is provided in the table below:
LIST OF OPERATING PARAMETERS
1
Return to the previous menu
2
Lights on/off
3
Diagnostic mode
4
Operating timers
5
Confirm
6
Increase
7
Decrease
1
Return to the previous menu
2
Increase value
3
Decrease value
4
Confirm
IMPORTANT
Incorrect setting of the parameters may compromise machine operation.
NAME
DESCRIPTION
UM
RANGE
DEFAULT
P00
:
LANG
Language in which the messages and alarms are displayed
-
-
ITALIAN
P01
:
TRP
Product reserve conservation temperature
°C/°F
8...0
5
P02
:
DS
Ice cream density
-
1…10
5
P03
:
V1
Electric motor rotation speed during ice cream preparation (total re-
duction ratio i=48:1)
rpm
500…6000
3000