10 PC – Control unit connection
Once finished with the system components definition part (previous chapters) you can move on to programming the control unit from
either the keypad or the PC via direct or remote connection.
10.1 Locally Programming the RS-232
STEP 1: Opening the control unit
1.
To access the Technical Menu press the
/ESC # key for 5 sec
followed by the User code (if under 6 digits confirm with
*
).
2. Press
the
/ESC # key for 5 sec and digit the Technical code..
3.
Open the control unit by loosening the apposite screws.
STEP 2: Placing the control unit in maintenance
To prevent alarms from being raised due to control unit tamper or due to
possible programming errors, we suggest placing the control unit into
maintenance mode.
1.
Place the control unit into maintenance mode
ON
1
by raising
microswitch 1.
+
1
2
3
4
5
6
7
8
–
+
–
U1 U2 U3 U4 NO
C
NC
T
–
F1
F5
+
A
B
BUS
+
IN
AUX
POS
M2
M3
P1
CN6
M6
M7
SW1
JP3
O.C
RELAY
TAMPER
Vac
M1
CN3
CN2
CN1
1 2 3 4
ON
+BA
T
–BA
T
JP1
CN5
CN4
STEP 3: Connecting the PC the control unit
1.
Install the control unit programming software onto your PC.
2.
Connect the control unit to the PC via a RS-232 standard cable
(direct male-female) or via a USB-RS232 cable.
STEP 4: PC setting (to do only once)
1.
Set connection to control unit via PC (LOCAL).
2.
Set the serial communications COM.
STEP 5: Control unit setting (to do only once)
There are two ways to program the control unit:
• With control unit shut down
• With control unit shut down after entering user code
To set one of the two modes you need to:
1.
To access the Technical Menu press the
/ESC # key for 5 sec
followed by the User code (if under 6 digits confirm with
*
).
2. Press
the
/ESC # key for 5 sec and enter the Technical code.
3. With
select
CODES
and press
*
.
4.
With
select
TECHNICAL CODE INSTALLER
and press
*
.
5. With
select
PROGRAM. FROM PC
.
6. With
+
and
–
edit the parameter:
•
FROM CTRL-U OFF
, direct programming without
entering user code with control unit off.
•
AFTER USER CODE
, programming only after entering user
code and with control unit shut down.
7. Press
#
to output and return to the previous menus.
08:23 16/05/10
ENTER CODE
123456
STANDING BY
*=USER MENU
222222
08:23 16/05/10
ENTER CODE
123456
STANDING BY
*=USER MENU
222222
CODES 16
TECHNICAL CODE
INSTALLER
*
▼ ▲
▼ ▲
PROGRAM. FROM PC
FROM CTL-U OFF
*
▼ ▲