9.7 Programming Inputs
Basic input parameters
1.
To access the Technical Menu, press the
/ESC # key for 5 sec
followed by the User code (if under 6 digits confirm with
*
).
2. Press
the
/ESC # key for 5 sec and enter the Technical code.
3. With
select
INPUTS
and press
*
.
4. With
select the input to set and press
*
.
5. With
select
STATUS
to set with
+
-
use of the input
INSERTED
(or, excluded, in test).
6. With
select
TYPE
to set with
+
-
the type of input
SWITCH ON
(or: delayed, …)
7. With
select
BALANCE
to set with
+
-
the type of
balancing
SINGLE BAL.
(or: NA, NC, …).
8. With
select
AREAS
to set the areas associated to the input
(use the numeric keys to select the areas; # =activated, - deactivated.
9.
With
select
DESCRIPTION
and press
*
.
10.
Use
the keys
to edit text
11.
Use the
+
-
keys to move down one character at a time.
12. Press
*
to confirm and return to previous menu. Press
#
to cancel
the change.
13. Press
#
to exit and return to the previous menus.
08:23 16/05/10
ENTER CODE
123456
STANDING BY
*=USER MENU
222222
INPUTS 11
CHANGE INPUTS XXX
INPUT XXX
*
▼ ▲
▼ ▲
STATUS XXX
INSERTED
*
TYPE XXX
SWITCH ON
BALANCING XXX
SINGLE BAL.
AREAS XXX
#--
DESCRIPTION XXX
INPUT XXX
SCENARIO XX
*=OK #=ESC
GOING OUT
*=OK #=ESC
*
*
▼ ▲
▼ ▲
▼ ▲
▼ ▲
+ -
+ -
+ -
+ -
Example:
Let’s say we have the following system with 5 inputs (one of which consists of shutters). In particular, we want to have the input to the
house delayed and the input radar instantaneous is delayed only when the front door is opened.
Area 1 = DAY AREA
Area 2 = NIGHT AREA
Area 3 = PERIMETER
EDIT INPUT 001
BEDROOM RADAR
STATUS 001
ENGAGED
*
TYPE 001
ISTANTANEOUS
BALANCING 001
SINGLE BALANCE
AREA 001
-#-
DESCRIPTION 001
BEDROOM RADAR
EDIT INPUT 002
FRONT DOOR RADAR
STATUS 002
ENGAGED
*
TYPE 002
PATH
BALANCING 002
SINGLE BALANCE
AREA 002
#--
DESCRIPTION 002
FRONT DOOR RADAR
EDIT INPUT 003
FRONT DOOR
STATUS 003
ENGAGED
*
TYPE 003
DELAYED 1
BALANCING 003
SINGLE BALANCE
AREA 003
--#
DESCRIPTION 003
FRONT DOOR
EDIT INPUT 004
LIVING ROOM RAD.
STATUS 004
ENGAGED
*
TYPE 004
ISTANTANEOUS
BALANCING 004
SINGLE BALANCE
AREA 004
#--
DESCRIPTION 004
LIVING ROOM RAD.
Bedroom radar
(Night area, instantaneous)
Front door radar
(Day area, path)
Living room radar
(Day area, instantaneous)
Front door contact