1
2
3
4
5
6
7
8
–
+
–
U1 U2 U3 U4 NO
C
NC
T
–
F1
F5
+
A
B
BUS
+
IN
AUX
POS
M2
M4
P1
CN6
M6
M7
SW1
JP3
O.C
RELAY
TAMPER
Vac
M1
CN3
CN2
CN1
1 2 3 4
ON
+BA
T
–BA
T
JP1
CN5
CN4
PXGSM
+
1
2
3
4
5
6
7
8
–
+
–
U1 U2 U3 U4 NO
C
NC
T
–
F1
F5
+
A
B
BUS
+
IN
AUX
POS
M2
M4
P1
CN6
M6
M7
SW1
JP3
O.C
RELAY
TAMPER
Vac
M1
CN3
CN2
CN1
1 2 3 4
ON
+BA
T
–BA
T
JP1
CN5
CN4
PXTEL
A
B
C
Control unit board
Proxinet8
Nylon rivets
Nylon O-ring
PXTEL boar
d
Page
25
- Installation Manual
24805490/11-01-2013 319F90C
ver
.
1.2 -
The data and information in this manual may be changed at any time with no obligation on BRAHMS’
s par
t t
o notify anyone of this
ENGLISH
INSTALLING
8.3 PXTEL
GENERAL CHARACTERISTICS
Power Supply
12 Vdc
Power draw
20 mA
Working temperature
0° - 40°C
Relative humidity
25% - 75% without condensation
CARD DESCRIPTION
DESCRIPTION
1
Board connector to control unit.
2
Terminal board for telephone line connection.
3
Red PSTN line status LED
〇
Off
Communication NOT active
●
On
Communication active
INSTALLING
All interface insertion and removal operations must be made when main power supply is cut off to control unit.
All interface insertion and removal operations must be made when main power supply is cut off to control unit.
All interface insertion and removal operations must be made when main power supply is cut off to control unit.
Power up control unit only after connecting the antenna and inserting the SIM card.
After powering up the control unit, let at least one minute elapse, check that the GSM’s green DL1 LED signals proper SIM registration
(
0.3 s ON / 2.7 s OFF)
.
Control unit board
Proxinet8
Nylon rivets
PX
GSM Boar
Nylon O-ring