9.1 First start up
+
1
2
3
4
5
6
7
8
–
+
–
U1 U2 U3 U4 NO
C
NC
T
–
F1
F5
+
A
B
BUS
+
IN
AUX
POS
M2
M3
P1
CN6
M6
M7
SW1
JP3
O.C
RELAY
TAMPER
Vac
M1
CN3
CN2
CN1
1 2 3 4
ON
+BA
T
–BA
T
JP1
CN5
CN4
Page
26
- Installation Manual
24805490/11-01-2013 319F90C
ver
.
1.2 -
The data and information in this manual may be changed at any time with no obligation on BRAHMS’
s par
t t
o notify anyone of this
ENGLISH
SYSTEM IN MAINTENANCE
SYSTEM UP AND OPERATIONAL
First line of the display reading “in
maintenance” message
First line of the display contains
control unit date and time
IN MAINTENACE
ENTER CODE
08:23 16/05/10
ENTER CODE
POWER ON CENTRAL
• Power up the control unit with 230 Vac and connect the battery.
• When first switched on the control unit follows the configuration of the parameter
POWER ON CENTRAL
which is
normally set to
TOTAL ON
.
• Switch off the system by keying in user code
123456
followed by the switching off button
D
.
CHANGE CONTROL UNIT LANGUAGE
The control unit can support the management of multiple languages through the PXLNG interface which allows installation of the
desired language.
To change the language see the section "Control Unit language update board PXLNG" in this manual.
Updating the language makes it possible to update the firmware as well.
9 Starting up the system
This chapter aims to describe how to start up a system in a “easy” way, with no particular configurations. It shows how to
install all of the components and programming of the basic functions (areas, scenarios, inputs, outputs, telephone warnings).
Before starting up system, do the following:
• Laying of RS485 control unit bus.
• Cabling inputs.
• Cabling outputs.
• Cabling the control unit.
• Cabling keypads, inserters, accessories, …
Below is an explanation of how to start up the system.
PRELIMINARY CHECKS
Check connections to ground and 230 Vac main power supply.
SYSTEM UNDERGOING MAINTENANCE / OPERATIONAL
To prevent accidental calls or sirens up when system undergoes maintenance jobs, setting the system to MAINTENANCE mode will
disable said warning functions.
The control unit under maintenance deactivates:
• Telephone calls and SMS text messages.
• Activating the alarm outputs.
The User Menu can be used to test any disabled functions.
Visualising the state of maintenance can only be done on LCD keypads.
To change maintenance / operational, operate on switch
[SW1.1]
ON
1
in maintenance
ON
1
operational