BP-PR PLUS series
Service functions
Edition 3/07
Configuration Instructions
53
6.6
Changing OEM name
You can change the device designation with the
OEM Name
function.
1. Insert service key into a USB master interface.
2. Press the
menu
button.
3. Select
Service
>
OEM Name
menu.
4. Press the
↵
button.
A list of available names is shown in the display.
5. Use the
S
and
T
buttons to select the desired
OEM name
.
6. Press the
↵
button.
6.7
Cleaning interval
The
Cleaning interval
function is used for additional printhead maintenance control. You can select
the length of medium which passes the printhead in increments of 500 m after which the printhead is to
be cleaned.
1. Insert service key into a USB master interface.
2. Press the
menu
button.
3. Select
Service
>
Cleaning interval
menu.
4. Press the
↵
button.
5. Select the desired value with the
X
and
W
buttons.
6. Press the
↵
button.
If the set length of the medium (label strip, transfer ribbon) has passed the printhead and an error occurs
in the flow of the medium (e.g. label end, transfer ribbon end), the
Clean printhead!
message
appears in the display. The error message for the error which occurred is not displayed until you
acknowledge this message. As long as no errors occur in the medium flow, no messages are displayed
and the print job is continued even if the cleaning interval has passed.
You can deactivate the
Cleaning interval
function by setting the value
Off
.
Access only when service key is inserted!