BP-PR PLUS series
Service functions
Edition 3/07
Configuration Instructions
51
5. Use the
S
and
T
buttons to select
Yes
.
6. Press the
↵
button.
The data recorded by the service counter is set to the value 0.
You can use the status print to check whether the values were reset. The service counter values are
listed in parentheses under the total counter values there.
6.3
Adjusting label sensor
You can adjust the label sensor with the
Adj. gap sensor
function. This is necessary if the sensor or
CPU PCB has been changed.
1. Insert service key into a USB master interface.
2. Press the
menu
button.
3. Select
Service
>
Adj. gap sensor
menu.
4. Press the
↵
button.
5. Open printhead.
In the display you are instructed remove the label medium from the sensor via the
Remove labels
message.
6. Remove label medium from the sensor.
7. Press the
↵
button.
In the display you are instructed to load the liner into the label sensor via the
Insert liner
mes-
sage.
8. Load liner (without labels) into the sensor.
9. Ensure that no labels are found on the liner near the sensor. Otherwise, the result will be faulty adjust-
ment and device malfunction.
10.Start adjustment of the label sensor with the
↵
button.
OK
appears in the display after a successful adjustment.
11.Confirm completion of the adjustment with the
↵
button.
Error during adjustment:
If an error occurs while adjusting the label sensor,
Error
appears in the display. If an error occurs again
when repeating the adjustment, one of the following assemblies may be defective:
•
Label sensor
•
Connection cable of the label sensor
•
CPU PCB
Access only when service key is inserted!
Carry out adjustment of the sensor with the cover closed and housing mounted to keep out external light
sources.