BP-PR PLUS series
Offline menu
Edition 3/07
Configuration Instructions
19
Tab. 7:
Menu structure
3.2
Navigating the offline menu
You can control all settings and functions in the offline menu with the navigator pad.
1st menu level
2nd menu level
Access
Service
Firmware upd.
PIN protection possible
Firmw. fr. card
PIN protection possible
Clr. service ctr.
Only with service key inserted
Adj. gap sensor
Only with service key inserted
Save settings
Only with memory card inserted,
PIN protection possible
Load settings
Only with memory card inserted,
PIN protection possible
OEM Name
Only with service key inserted
Cleaning interval
Only with service key inserted
Fig. 5:
Navigator pad
⇒
Press the
menu
button to switch from
Ready
mode to the offline menu.
⇒
Press the
X
or
W
button to select menu items on a menu level or to select
values on the parameter level.
⇒
Press the
W
button on the top menu level several times, if necessary, to
switch from the offline menu to
Ready
mode.
⇒
Press the
S
or
T
button to reach a higher or lower menu level or to set
values on the parameter level.
⇒
Press the
↵
button briefly to enable value selection on the parameter level,
accept a selected value or start a function.
⇒
Press and hold (> 2 sec.) the
↵
button to exit the parameter level without
accepting the parameter setting.
You can also make all settings in the offline menu via the Ethernet interface (see "4.2" on Page 28) or
via direct control commands (see
“Programming Manual“
).