Classic Terrazzo
®
Corner Washfountain with Touch Time™ Control
Installation Instructions
WF2613
Bradley Corporation • 215-1520 Rev. D; EN 06-915B
9
4/6/2007
Installation Instructions continued . . .
Step 4a: Installing Supplies with Optional Soap Dispenser for A/O drain units
NOTE: See Step 4b on page 11 for Type B/H drain units.
NOTE: For models with optional paper towel dispensers, tie pipe assembly, or shroud, see separate
instruction sheets and Step 4b for units with type B/H drain.
1. Install hemmed end (not sharp end) of support tube (welded seam toward intersection of walls)
with gasket onto bowl as shown in Figure 7 on page 10.
2. Install restraining bracket on the support tube above the backsplash as shown in Figure 7 on
page 10. Use suitable anchors to attach to wall.
3. Connect 1/2" supply tubing to sprayhead as shown in Figure 6. Follow the procedures below
when installing 1/2" tubing into sprayhead to ensure that you achieve a leakproof seal.
• Using a sharp knife, cut tubing squarely and remove any burrs.
DO NOT
pinch or crush end of tubing.
• Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated.
Tighten nut to secure tube to fitting (make sure nut is securely tightened).
• If connector leaks, reseat tubing according to above procedure. If leaking persists, replace
male connector, or call your Bradley representative for assistance.
4. Place sprayhead with 1/2" tubing onto support tube as shown in Figure 7. Run tubing down
through support tube.
Make sure spray holes point away from the wall.
5. Assemble the lower tie rod (the longer threaded rod), upper tie bar (notched at corners), lower tie
bar, tie rod nut, and coupling nut, then attach the 4-1/4" tie rod to coupling nut as shown in
Figure 7. Make sure upper tie bar is positioned as shown in Figure 7 on page 10.
6. Connect the four wires from the Touch Time switch in the Touch Time module assembly to the
terminal block as shown in Figure 10 on Page 14.
7. Place Touch Time module assembly on top of sprayhead. Rotate until module locks in with tie
bar with pushbutton facing front of bowl. Drop the terminal block with the wires attached into
the pedestal.
8a.
FOR UNITS WITH SOAP OPTION:
Install the spacer, soap dispenser and dispenser cover
using the coupling nut, third tie rod (8-5/8" long) and second coupling nut as shown in Figure 7.
Secure with acorn nut and socket head set screw.
8b.
FOR UNITS WITHOUT SOAP OPTION:
Secure module cover and dispenser cover with
acorn nut and socket head set screw.
9. Continue installation with Step 5 on page 13.
NUT
TUBING
MALE
1/2" TUBE
CONNECTOR
269-626
SPRAYHEAD
TUBING
Figure 6