Step 4b: Installing Supplies with Optional Soap Dispenser for B/H drain units
NOTE: Flush the supply lines before making connections.
1. Install hemmed end (not sharp end) of support tube (welded seam toward intersection of walls)
with gasket onto bowl as shown in Figure 8 on Page 12.
2. Connect 1/2" supply tubing to sprayhead as shown in Figure 6 on page 9. Follow the procedures
below when installing 1/2" tubing into sprayhead to ensure that you achieve a leakproof seal.
• Using a sharp knife, cut tubing squarely and remove any burrs. DO NOT pinch or crush end of
tubing.
• Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated. Tighten
nut to secure tube to fitting (make sure nut is securely tightened).
• If connector leaks, reseat tubing according to above procedure. If leaking persists, replace male
connector, or call your Bradley representative for assistance.
3. Place sprayhead with 1/2" tubing onto support tube as shown in Figure 8. Run tubing down
through support tube.
Make sure spray holes point away from the wall.
4. Place air module assembly on top of sprayhead. Make sure pushbutton is facing the front of the
unit.
5. Run the 1/8"tubing through the support tube into the pedestal.
6. Insert the 1-1/2" vent pipe (supplied by installer, see page 3 for length) through the air module,
sprayhead, and support tube.
7. Connect to vented trap provided.
8a.
FOR UNITS WITH SOAP OPTION:
Place the spacer, soap dispenser and cover in position on
top of air module (see Figure 8). Slide tie bar over 1-1/2" vent pipe 1/2" below top of soap
dispenser lid and secure with set screws (tie bar must be positioned as shown in Figure 8). Slide
the dispenser cover over 1-1/2" vent pipe and secure with 2 screws included with tie bar.
8b.
FOR UNITS WITHOUT SOAP OPTION:
Slide tie bar over 1-1/2" vent pipe, 1/2" below top
of air module and secure with set screws (tie bar must be positioned as shown in Figure 8). Slide
the dispenser cover over 1-1/2" vent pipe and secure with 2 screws included with tie bar.
9. Connect vent pipe to vent through ceiling with pipe union.
10. Continue installation with Step 5 on page 13.