Classic Terrazzo
®
Corner Washfountain with Foot Control
Installation Instructions
WF2613
Bradley Corporation • 215-609 Rev. J; EN 06-915B
13
4/6/2007
Installation Instructions continued . . .
Step 5: Installing the Drain
NOTE: Flush the supply lines before making connections.
1. Assemble the stop-strainer-check valves, mixing valve, volume control valve and foot valve to
the supplies as shown in Figure 10 at the approximate height indicated in Table 1.
DISTANCE TO FINISHED FLOOR
Model
Type A
Type B
Type O
Type H
Standard Height
9" (229mm)
6-3/16 (157mm)
9" (229mm)
6-3/16 (157mm)
Juvenile Height
5-1/4" (133mm)
3-7/16 (87mm)
5-1/4" (133mm)
3-7/16 (87mm)
Table 1
Operating Lever
Coupling
(169-174)
Nut
(110-005)
Tailpiece
(129-009)
Nipple
STD: 2" Long (113-852)
JUV: Close (113-006AL)
Tailpiece Washer
(124-001AF)
Used on "B"
and "H" models only
To Supply Pipe
Foot Valve
(S07-066)
OPTIONAL Vernatherm™
Thermostatic
Mixing Valve
(S01-525)
(Units are supplied with
Manual Mixing Valve as
standard equipment)
Stop-Strainer-Check
Valve
(S60-003)
Washer
(124-001AF)
Nut
(110-005)
Tailpiece
(129-007)
Manual Mixing
Valve
(S01-038)
Valve Assembly
Distance (dimension)
finished floor - see
Table 1
Figure 10