Classic Terrazzo
®
Corner Washfountain with Foot Control
Installation Instructions
WF2613
Bradley Corporation • 215-609 Rev. J; EN 06-915B
11
4/6/2007
Installation Instructions continued . . .
Step 4b: Installing Supplies for B/H drain units
NOTE: Flush the supply lines before making connections.
1. Install the hemmed end (not sharp end) of the support tube (welded seam toward intersection of walls)
with gasket into the bowl (see Figure 9 on page 12).
2. Using pipe sealant, connect the supply pipe to the sprayhead and place on top of the support tube.
Run tubing down through the support tube.
Make sure spray holes point away from the wall.
3. Insert the 1-1/2" vent pipe (supplied by installer, see page 3 for length) through the soap
dispenser with the spacer (if provided), sprayhead, and support tube.
4. Connect to the vented trap (provided).
5a
.
For Unit with Soap Option:
1. Slide the tie bar over the 1-1/2" vent pipe 1/2" below the top of the soap dispenser and secure
with the set screws. (Tie bar must be as shown in Figure 9).
2. Slide the dispenser cover over the 1-1/2" vent pipe and secure with the two screws (included) to
the tie bar.
5b
.
For Unit without Soap Option:
1. Slide the tie bar over the 1-1/2" vent pipe, 1/2" below the top of the sprayhead and secure with
the set screws. (Tie bar must be as shown in Figure 9).
2. Secure the dispenser cover over the 1-1/2" vent pipe and secure with the two screws included
with the tie bar.
6
.
Connect the Vent Pipe
a. Connect the vent pipe to the vent through the ceiling with the pipe union.
b. Continue installation with Step 5 on Page 13.