Material
A
B
C
D
E
F
G
H
J
K
Inches
19
29-1/4
39-1/8
47-5/8
36-1/4
56
26
28
37-1/4
10-1/4
Millimeters
483
743
994
1210
921
1422
660
711
946
260
Classic Terrazzo
®
Corner Washfountain with Foot Control
Installation Instructions
WF2613
Bradley Corporation • 215-609 Rev. J; EN 06-915B
3
4/6/2007
Length of Tie Pipe Required for Vent through Washfountain Column
54" Less Soap Dispenser
21-1/2" (546mm)
54" With Soap Dispenser
30" (762mm)
54" Less Soap Dispenser With Towel Dispenser
55-1/2" (1410mm)
54" With Soap Dispenser With Towel Dispenser
48" (1219mm)
54" With Cube Adapter
32" (813mm)
54" With Cube Adapter With Towel Dispenser
50" (1270mm)
54" With Cube Adapter And Soap Dispenser
40" (1016mm)
Type
Pipe Length
NOTE: Drain must be connected with 2" schedule 40 welded wrought iron pipe, minimum, to provide
lower support for this installation. Vent or support pipe must be of the same material in 1-1/2".
For juvenile height, subtract 4" from dimensions A-E.
Corner Washfountain Dimensions
6" (152)
ADJUST TO TOWEL DISPENSER
MOUTING HOLES
K
E
J
H
G
A
B
C
D
F