Classic Terrazzo
®
Corner Washfountain with Air Valve Control
WF2613
Installation Instructions
Bradley Corporation • 215-1523 Rev. E; EN 06-915B
14
4/6/2007
Installation Instructions continued . . .
Step 6: Adjust the air valve metering time
Note: The air valve timer is located next to the tube connector on the air valve body. The timer is capped
with a filter to prevent dirt build-up on the timer. The air valve timing can be adjusted from 5-45 seconds.
Refer to Figure 11 when adjusting the air valve.
1. Remove the filter cap. Use a screwdriver to tighten or loosen the timer. Turning the timer
clockwise increases the time, turning the timer counterclockwise decreases the time.
2. Continue to adjust the timer until it is set at the desired length.
3. Replace the filter cap.
Figure 11
RELEASE
BUTTON
GRIPPING
RIDGE
LOCKING
SLOPE
1/8”
TUBING
TUBE
STOP
SEALING
RING
Figure 10