Classic Terrazzo
®
Corner Washfountain with Infrared Control
WF2613
Installation Instructions
Bradley Corporation • 215-1451 Rev. D; EN 06-915B
2
4/6/2007
Pre-Installation Information
Infrared Control
Hands placed within the bowl are detected by an infrared sensor module which activates a solenoid
valve starting the flow of tempered water from the sprayhead. Shut-off is automatic seven seconds
after hands are removed from the detection area.
Supplies Required:
• (6) lag bolts, screws or other fasteners to anchor washfountain pedestal to floor.
• 1" hot and cold water supply lines and fittings (refer to rough-ins on pages 4-5).
• Reducing fittings and 1/2" nominal copper tubing for models with supplies from above.
• Standard P-trap (refer to rough-ins on pages 4-5). Vented trap supplied by Bradley when
required.
• 2" drain lines and fittings (refer to rough-ins on pages 4-5).
• Pipe sealant and plumber’s putty.
• 1-1/2" vent pipe on types vented through washfountain column (see page 3 for lengths required).
• 110 VAC GFI power source for 110/24 VAC UL CLASS II transformer supplied
• OPTIONAL: Bradley recommends installing an electrical cut-off switch to the unit. This
feature prevents accidental water delivery during regular maintenance and service
NOTE: Supply lines for one or two washfountains should be 1"; for three washfountains, 1-1/4". For
more than three washfountains pipe size should increase proportionally. Vent pipe to be 1-1/2" on
models vented through washfountain.
Bradley Classic Washfountain Warranty Information