Collector installation
6 720 613 057 (2006/04)
24
6.1.2 Fitting the end cap
Not all the connections are needed when connecting
a collector array. Those that are not used must be
closed.
B
Remove rubber caps (transport protection) from the
relevant collector connections.
B
Push end cap with the O-rings (Fig. 20, Item 1) onto
the collector connection.
B
Push bracket (Fig. 20, Item 2) over the end cap and
collector connection to secure the connection.
6.1.3 Inserting sealing tape in collector frame
The connections between the side and lower facing pan-
els and the collectors (Fig. 21, Item 1) must be sealed
with the sealing tape.
B
Clean the recessed channel on the collector.
B
Remove protective film from the sealing tape
B
Insert sealing tape (Fig. 21, Item 2) adhesive side
first into the recessed channel on the outer edges of
the outer collectors and at the bottom of every collec-
tor (Fig. 21, Item 1) incl. the corner connector
(Fig. 21, Item 3).
The sealing tape slowly swells after installation.
Fig. 20
Securing end cap with bracket
63043966.12-1.SD
63043966.12-1.SD
2
1
CAUTION!
SYSTEM DAMAGE
from unsecured locking caps.
B
Secure each locking cap with
a bracket (Fig. 20, Item 1).
Fig. 21
Back of the collector
63043973.02-1.SD
63043973.02-1.SD
2
1
1
1
1
3