Collector installation
6 720 613 057 (2006/04)
26
Fitting corrugated pipe connectors to the first
collector
B
Remove the rubber caps from the connections.
B
Push corrugated pipe connectors (Fig. 45, Item 1)
onto the left-hand connections on the first collector.
B
Push bracket (Fig. 45, Item 2) over the corrugated
pipe connector and collector connection to secure
the connection.
Putting the second collector in place
B
Place the second collector onto the profile rails and
allow it to slide into the anti-slip protectors.
B
Push the second collector on to the first in such a way
that the collector connections are pushed into the
preassembled corrugated pipe connectors (Fig. 25,
Item 1) on the first collector.
B
Place second bracket (Fig. 25, Item 3) over the
corrugated pipe connector and collector connection.
63043966.11-1.SD
63043966.11-1.SD
Fig. 25
Pushing second collector towards the first
2
63043966.15-1.SD
63043966.15-1.SD
1
2
3
CAUTION!
SYSTEM DAMAGE
through damaged corrugated pipe
connectors.
B
Do not use any tools, e.g. pliers
(Fig. 25, Item 2). These could render
the corrugated pipe connector
unusable.
Fig. 26
Corrugated pipe connector secured with brackets
63043966.16-1.SD
63043966.16-1.SD
1
CAUTION!
SYSTEM DAMAGE
through unsecured corrugated pipe
connectors and end caps.
B
Secure each end cap with one bracket
and each corrugated pipe connector
with two brackets (Fig. 26, Item 1).
Summary of Contents for Worcester FKT Series