Quick reference guide for two collectors
6 720 613 057 (2006/04)
42
12 Quick reference guide for two collectors
These instructions are only intended as an overview of
the work to be carried out. You MUST follow the detailed
descriptions for the work on the pages mentioned, and
obey all safety and user instructions.
Fig. 60
Roof preparations
Fig. 61
Pipework connections
Fig. 62
Fastening and covering two collectors
X
X
63043975.44-1.SD
63043975.44-1.SD
1
2
3
3
3
3
3
3
63043966.31-1.SD
63043966.31-1.SD
11
11
4
16
12
6
15
4
16
63043975.45-1.SD
63043975.45-1.SD
20
7
7
7
10
10
10
14
14
20
21
22
22
19
2
23
24
19
Roof preparations
1.
Mark dim. X on the roof.
p. 17
2.
Installation of anti-slip protection devices
p. 19
3.
Attach additional roof battens to the roof.
p. 19
Preparing to install the collectors
4.
Push locking caps onto those connections that are
not required and secure using clips.
p. 24
5.
Insert sealing tape into the recessed chanel on the col-
lector frame (at the bottom, and on the outside edges of
the collector array).
p. 24
Fastening the collectors
6.
Allow first collector (right) to slide into the anti-slip
protection devices, 80 mm from the pan tiles.
p. 25
7.
Push underlay plates under the collector and drill pilot
hole for a screw.
p. 25
8.
Fasten clamp with screw and washer.
p. 25
9.
Drill hole for the double-sided clamp on the left
collector side (between two collectors).
p. 25
10.
Push underlay plate under collector and screw in the
double-sided clamp a little.
p. 25
11.
Push corrugated pipe connectors onto the
connections on the first collector and secure with clips.
p. 25
12.
Push second collector towards the first and fit
second clip.
p. 26
13.
Tighten screws on the double-sided clamp.
p. 27
14.
Fit one-sided clamps on the left
p. 27
Header connection
15.
Insert collector sensor as far as it will go into the collec-
tor with the flow line to be connected, and screw tight.
p. 28
16.
Push connection pipes onto flow and return connec-
tions and secure with clips.
p. 29
17.
Feed flow connection pipe together with sensor
cable through de-airing tile and roof insulation.
p. 29
18.
Perform installation checks.
p. 33
Installing the facing panel
19.
Insert lower facing panels from right to left and
fasten with plumbing screws.
p. 34
20.
Insert side panels and fix in place with clips.
p. 36
21.
Latch cover strip between collectors and tighten
screws by hand.
p. 36
22.
Insert upper facing panels from right to left, cut
rubber lip and insert into right-hand facing panel.
p. 38
23.
Fasten upper facing panels with clips and fix to
the overlaps with screws.
p. 39
24.
Fit pan tile overlay and cut pan tiles to size.
p. 40