Installing the facing panels
6 720 613 057 (2006/04)
33
10 Installing the facing panels
Before you block access to the collector array with the
facing panels, you must carry out the following checks:
To seal the collector array, facing panels must be fitted
around and between the collectors/collector arrays.
1.
Solar hoses secured with clips?
2.
Every collector secured on the left and right
with clamps?
3.
Sensor inserted as far as it will go and se-
cured with clamped joint?
4.
Pressure test carried out and all connections
leak-proof (see pump station instructions)?
CAUTION!
BUILDING DAMAGE
from leaks in the roof.
B
Fit the facing panels very carefully,
so that no leaks can occur through
the collector array.
Fig. 40
Facing panels fitted all round the edges
63043975.09-1.SD
63043975.09-1.SD
1
CAUTION!
RISK OF INJURY
Like other components incorporated into
the roof, the space between the collector
and the pan tiles is covered with thin
panels. These can cause injuries.
B
Wear suitable gloves to protect your
hands.
i
USER NOTE
For horizontal installation, the lower, mid-
dle and upper facing panels do not over-
lap between two collectors (Fig. 40,
Item 1), but in the middle of a collector.