74
en | Configuration using a Web browser
VideoJet XF E
DOC | V5.51 | 2012.03
Installation and Operating Manual
Bosch Sicherheitssysteme GmbH
5.38
Advanced Mode: Alarm Inputs
You can configure the alarm inputs of the VideoJet XF E.
Alarm input
Select
N.O.
if the alarm is to be triggered when the contact closes. Select
N.C.
if the alarm is
to be triggered when the contact opens.
Name
You can enter a name for each alarm input. If the
LIVEPAGE
functions are configured
accordingly, this name is displayed below the icon for the alarm input. You can also use the
name in the Forensic Search program function as a filter option for quick search in recordings.
Enter a unique and clear name here.
Further topics:
–
Section 5.15 Advanced Mode: LIVEPAGE Functions, page 38
5.39
Advanced Mode: Relay
You can configure the switching behavior of the relay output. You can specify an open switch
relay (normally closed contact) or a closed switch relay (normally open contact).
You can also specify whether the output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state.
CAUTION!
Do not use any special characters, for example
&
, in the name.
Special characters are not supported by the system's internal management.