Carefully slide the SD card into the slot as far as it will go, until it locks into place.
2.
To remove the SD card, push carefully in the direction of insertion until the mechanical
catch releases and then remove the card.
Data interface
The bidirectional data interface is used to control units connected to the VIP X1 XF, such as a
dome camera with a motorized lens. The connection supports the RS-232, RS-422 and RS-485
transmission standards.
The VIP X1 XF offers the serial interface via the orange terminal block (see
Section 8.8 Terminal block, page 117
).
The range of controllable equipment is expanding constantly. The manufacturers of the
relevant equipment provide specific information on installation and control.
Alarm inputs
The VIP X1 XF standard version has two alarm inputs on the orange terminal block, the Eco-
version has one alarm input (see
Section 8.8 Terminal block, page 117
). The alarm inputs are
used to connect to external alarm devices such as door contacts or sensors. With the
appropriate configuration, an alarm sensor can automatically connect the VIP X1 XF to a
remote location, for example.
A zero potential closing contact or switch can be used as the actuator.
Connect the lines to the appropriate terminals on the orange terminal block (standard
version:
IN1
and
IN2
, Eco-version:
IN
) and check that the connection is secure.
Relay outputs
The VIP X1 XF standard version has two relay outputs for switching external units such as
lamps or alarm sirens. The Eco-version has one relay output. You can operate these relay
outputs manually while there is an active connection to the VIP X1 XF. The outputs can also be
configured to automatically activate sirens or other alarm units in response to an alarm signal.
The relay outputs are also located on the orange terminal block (see
Section 8.8 Terminal
block, page 117
).
Connect the lines to the appropriate terminals on the orange terminal block (standard
version:
R1
and
R2
; Eco-version:
R
) and check that the connection is secure.
CAUTION!
Please take note of the appropriate documentation when installing and operating the unit to
be controlled.
The documentation contains important safety instructions and information about permitted
uses.
NOTICE!
A video connection is necessary to transmit transparent data.
NOTICE!
If possible, use a bounce-free contact system as the actuator.
CAUTION!
A maximum load of 30 V
p-p
and 200 mA (SELV) may be applied to the relay contacts.