Trigger
You can select one of the physical alarms on the device's alarm inputs or one of the virtual
alarms as a trigger. A virtual alarm is created using software, with RCP+ commands or alarm
scripts, for example.
Trigger active
Select the VCA configuration here that is to be enabled via an active trigger. A green check
mark to the right of the list field indicates that the trigger is active.
Trigger inactive
Select the VCA configuration here that is to be activated if the trigger is not active. A green
check mark to the right of the list field indicates that the trigger is inactive.
Delay [s]
Select the delay period here for the reaction of the video content analysis to trigger signals.
The alarm is only triggered after a set time interval in seconds has elapsed and then only if the
triggering condition still exists. If the original condition has been restored before this time
interval elapses, the alarm is not triggered. A delay period may be useful in avoiding false
alarms or frequent triggering, for example. During the delay period, the
Silent
configuration is always enabled.
5.32
Advanced Mode: Audio Alarm
NOTICE!
For more information, please see the
Alarm Task Script Language
document and the RCP+
documentation. You can find these documents on the product CD supplied (see
Section 3.1 Scope of delivery, page 9
).