Advanced Mode: VCA Event triggered
This configuration allows you stipulate that the video content analysis is only to be activated
when triggered by an event. As long as no trigger is activated, the
Silent
configuration in which metadata is created is active; this metadata facilitates searches of
recordings, but does not trigger an alarm.
Trigger
You can select one of the physical alarms on the device's alarm inputs or one of the virtual
alarms as a trigger. A virtual alarm is created using software, with RCP+ commands or alarm
scripts, for example.
NOTICE!
For more information, please see the
Alarm Task Script Language
document and the RCP+
documentation. You can find these documents on the product CD supplied.