AutoDome 800 Series HD PTZ Camera
Alarms and Relay Connections | en
55
Bosch Security Systems, Inc.
Installation Manual
F.01U.273.797 | 5.0 | 2012.08
Figure 5.2
N.C. Normally Closed Non-supervised Connections
2.
From the Alarm Connections page on the Settings Page (
Section 7.39 Alarm Connections,
page 95
) the Alarm Input # to N.C. See the table below for contact and condition details.
5.3
Configuring an Open Collector Output
The AutoDome incorporates one (1) open collector output.
This output must be connected to a positive voltage between 5 and 32 V to complete the
circuit, with a maximum voltage rating of 32 VDC @ 150 ma.
1.
Connect the appropriate stripped wire to the open connector (1, 2, or 3) of the
transistor.
2.
Connect the appropriate stripped wire to the ground (GND) connector.
1
Dry Contact
3
Dome Connector
2
Alarm Inputs 1 to 2
4
Ground
AutoDome Programmed N.C.
Circuit
Alarm Indication
Open
Alarm
Closed
Normal