AutoDome 800 Series HD PTZ Camera
Installing Roof Parapet and Pipe Mounts | en
37
Bosch Security Systems, Inc.
Installation Manual
F.01U.273.797 | 5.0 | 2012.08
3.4
Route Wires and Attach Connectors
Power wires must be routed to the left (front) side of the Power Supply Box through a
separate conduit. All video, control, and alarm wires must be routed through a second conduit
to the right side of the box. See
Section 4 Cable and Wire Standards, page 51
for methods of
transmitting video and data, and for wire specifications.
There are two possible methods to route the video, control, and alarm wires:
–
One is to route the power, ethernet, and alarm wires through the conduit fitting on the
right (front) side of the Power Supply Box and out to the AutoDome Interface Board.
Figure 3.3
VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box
–
The second method is to bypass the Power Supply Box and route the ethernet and alarm
wires directly to the Interface Board. You connect only the power wires inside the Power
Supply Box.
WARNING!
External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for
US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
1
120 VAC/230 VAC Power In
5
Ethernet Video and Control Wire
2
P101 Connector
6
24 VAC Power Out
3
Ground Connection
7
P107 Connector
4
Transformer
GND TXD
RXD
C+
C-
GND TXD
RXD
C+
C-
P101
P106
P105
P107
XF102
X
F103
XF101
5 4 3 2 1
J
J
J103
J102
J101
(LED)
HTR DOME
24V NC 24V
(FUSE
)
(FUSE
)
(FUSE
)