70
en | Cable and Wire Standards
AutoDome 600 Series Analog PTZ Camera
F.01U.265.793 | 2.0 | 2012.02
Installation Manual
Bosch Security Systems, Inc.
The figure below illustrates the connections necessary for Biphase operation.
Figure 5.2
Connections for Biphase Operation
In a daisy chain configuration, where multiple domes are connected in series, the 100 Ω
resistor must be removed from all but the last dome. You can daisy chain a maximum of four
(4) AutoDomes.
Figure 5.3
Connections for a Daisy Chain Configuration
1
C- (Biphase)
7
AutoDome Data In/Out
2
C+ (Biphase)
8
Head End Biphase
3
Earth Ground
9
P105/P106 Connector
4
RxD
10
C- (Biphase)
5
TxD
11
C+ (Biphase)
6
Signal Ground
12
Shield
1
C- (Biphase)
9
Dome 3
2
C+ (Biphase)
10
Dome 2
3
Earth Ground
11
Dome 1
4
RxD
12
Head End Biphase
5
TxD
13
C- (Biphase)
6
Signal Ground
14
C + (Biphase)
7
Last Dome Data In/Out
15
Shield
8
P105/P106 Connector
100
Ω
100
Ω
Summary of Contents for VG5 600 Series